Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Chinese Journal of Tissue Engineering Research ; (53): 595-601, 2016.
Article in Chinese | WPRIM | ID: wpr-672258

ABSTRACT

BACKGROUND: Greatly importance has been attached to ceramic-on-ceramic bearing surface due to its excel ent wear resistance. But the risks of squeaking and ceramic fracture also go with it. Up til now, the choice between ceramic-on-ceramic and ceramic-on-polyethylene bearing surfaces in primary total hip arthroplasty remains controversial. OBJECTIVE: To compare the clinical outcomes and safety between ceramic-on-ceramic versus ceramic-on-polyethylene bearing surfaces in total hip arthroplasty based on meta analysis. METHODS: We electronical y searched databases including PubMed/Medline, Embase, Web of Science, Cochrane Col aboration database, Chinese Biomedical Literature Database (CBMdisc) and China National Knowledge Internet for randomized control ed trials on the comparison between ceramic-on-ceramic versus ceramic-on-polyethylene bearing surfaces in total hip arthroplasty from inception to January 2015. References of the included studies were also retrieved. Investigators severely selected the studies, extracted data and assessed the quality according to the inclusion and exclusion criteria. Then, meta-analysis was performed using RevMan 5.2 software. RESULTS AND CONCLUSION: Nine randomized control ed trials were included, involving 1 231 hips with ceramic-on-ceramic prosthesis and 932 hips with ceramic-on-polyethylene prosthesis. Meta analysis showed that both bearing surfaces achieved satisfied function recovery. But ceramic-on-ceramic had significantly increased risks of squeaking and ceramic fracture, meanwhile ceramic-on-polyethylene showed significantly higher wear rate. There were no significant differences in intra- or post-operative dislocation, osteolysis and other complications and prosthesis failure with any reason between two bearing surfaces. These results suggest that during the short- to mid-term fol ow-up period, no sufficient evidence can tel that ceramic-on-ceramic was obviously super than ceramic-on-polyethylene. Long-term fol ow-up is required for further evaluation.

2.
Chinese Medical Journal ; (24): 2524-2529, 2016.
Article in English | WPRIM | ID: wpr-230926

ABSTRACT

<p><b>BACKGROUND</b>Accuracy of implant placement in total knee arthroplasty (TKA) is crucial. Traditional extramedullary alignment instruments are fairly effective for achieving the desired mean tibial component coronal alignment. We modified the traditional tibial plateau resection technique and evaluated its effect on alignment restoration.</p><p><b>METHODS</b>Two hundred and eighty-two primary TKAs in our hospital between January 2013 and December 2014 were enrolled in this retrospective study. Group A consisted of 128 primary TKAs performed by one senior surgeon. Preoperative measurement of the tibial resection was conducted on radiographs, and the measured thicknesses of the lateral and medial plateau resection were used to place the tibial alignment guide. Group B consisted of 154 primary TKAs performed by the other senior surgeon, using a traditional tibial plateau resection technique. In all patients, an extramedullary guide was used for tibial resection, and preoperative and postoperative full-leg standing radiographs were used to assess the hip-knee-ankle angle (HKA), femoral component alignment angle (FA), and tibial component alignment angle (TA). A deviation ≥3° was considered unsatisfactory. Data were analyzed by unpaired Student's t-test.</p><p><b>RESULTS</b>The mean postoperative HKA and TA angles were significantly different between Groups A and B (178.2 ± 3.2° vs. 177.0 ± 3.0°, t = 2.54, P = 0.01; 89.3 ± 1.8° vs. 88.3 ± 2.0°, t = 3.75, P = 0.00, respectively). The mean postoperative FA was 88.9 ± 2.5° in Group A and 88.9 ± 2.6° in Group B, and no significant difference was detected (t = 0.10, P = 0.92). There were 90 (70.3%) limbs with restoration of the mechanical axis to within 3° of neutral alignment and 38 (29.7%) outliers (>3° deviation) in Group A, whereas there were 89 (57.8%) limbs with restoration of the mechanical axis to within 3° of neutral alignment and 65 (42.2%) outliers (>3° deviation) in Group B. The severity of the preoperative alignment deformity was a strong predictor for postoperative alignment.</p><p><b>CONCLUSIONS</b>Using conventional surgical instruments, preoperative measurement of resection thickness of the tibial plateau on radiographs could improve the accuracy of conventional surgical techniques.</p>


Subject(s)
Aged , Female , Humans , Male , Arthroplasty, Replacement, Knee , Methods , Bone Malalignment , Knee Joint , General Surgery , Postoperative Period , Retrospective Studies , Tibia , General Surgery
3.
Chinese Journal of Surgery ; (12): 1069-1073, 2010.
Article in Chinese | WPRIM | ID: wpr-360709

ABSTRACT

<p><b>OBJECTIVES</b>To analyze the reason of revisions no more than 5 years after primary hip replacement, and to discuss the methods how to prevent and manage.</p><p><b>METHODS</b>Retrospectively review 11 cases with revision no more than 5 years after primary total hip replacement from January 2002 to June 2007. The reasons for revision were as follows: 2 cases were recurrent dislocation due to malposition of acetabular prosthesis; 5 cases were loosening of acetabular prosthesis; 1 case was abrasion of the native acetabulum by bipolar femoral head; 2 cases were periprosthetic femoral fractures and 1 case was periprosthetic infection. The average follow-up time was 36 months. Each patient was assessed according to Harris hip score. The revision procedures including liner only, acetabular prosthesis only, or both acetabular prosthesis and femoral prosthesis depending on the reasons for revision, two-stage revision was performed on 1 case with periprosthetic infection.</p><p><b>RESULTS</b>The average of Harris hip score was increased from 46 (28 to 62) preoperatively to 86 (75 to 96) at follow up. The complication occurred in 2 cases: one was postoperative haematoma formation who was performed further surgery for clearance of haematoma, another was slight instability of the hip joint who was accepted skin traction for 3 weeks.</p><p><b>CONCLUSIONS</b>The main reason for revision after primary total hip replacement is related to uncorrected insert of acetabular prosthesis. Improving surgical technique of insert of acetabular prosthesis is important in primary total hip replacement.</p>


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Arthroplasty, Replacement, Hip , Follow-Up Studies , Postoperative Complications , General Surgery , Prosthesis Failure , Reoperation , Retrospective Studies , Treatment Outcome